The Problem: The heater needed an extensive revamp that included replacing the coil and other modifications to improve performance.
The Solution: After discussions with the customer, XRG and the customer agreed a complete replacement of the heater was more economical. XRG designed and supplied a new heater that incorporated:
The customers targeted efficiency for the new heater was 85.8% and XRG guaranteed 87.1%. If the customer operates within design limits, 61,320 lb of fuel is saved annually based on this higher efficiency.
“The plant is very happy with the result! Thanks to you and your team for all the hard work and overtime that made it possible to complete the project on such a short time frame!” – Customer’s Project Manager
XRG successfully replaced the heater in 5 months to meet the customer’s short turn-around schedule.
This project is an example of the true engineering partner XRG is committed to being to its customers!